Home  ›  Products  ›  Pipe & Cable Locator  ›  Genny4 Signal Transmitter
Radiodetection C.A.T4 Range

Genny4 Signal Transmitter

The Genny4 is the signal generator that turns a C.A.T4 into a complete locating system. Its patented dual-frequency output and Signal Boost make small, deep and difficult cables far easier to find — apply the signal by induction, direct connection or clamp.

Best forSignal application and small-cable location as one gCAT4 system with C.A.T4 and SuperC.A.T4
GENNY4 Transmitter - Signal Booster for ease of locating utility
Dual-FrequencyPatented simultaneous dual-frequency output that C.A.T4 detects on both signals at once
Signal BoostPower boost pushes the locate signal further and deeper, coupling onto utilities more easily
3 ModesApply the signal by induction, direct connection or signal clamp to suit the site
gCAT4Designed to work as one system with the C.A.T4 and SuperC.A.T4 cable avoidance tools
The gCAT4 System

The Genny4 And C.A.T4 Work As One.

A C.A.T4 on its own finds signals that already radiate underground. Pair it with a Genny4 and you can apply your own known signal to a target line — then trace it accurately. Because every C.A.T4 reads the Genny4’s dual frequencies simultaneously, even small-diameter cables and spurs stand out clearly.

  • Applies a traceable dual-frequency signal to the target line.
  • Induction, direct connection or clamp for any site condition.
  • Signal Boost extends depth and distance on difficult runs.
TransmitGenny4

Applies the dual-frequency locate signal, with Signal Boost for depth and distance.

+
DetectC.A.T4 / SuperC.A.T4

Reads both Genny signals at once to trace and avoid buried utilities before you dig.

Signal Application

Three Ways To Put The Signal On The Line.

The Genny4 energises the target utility using whichever method the site allows — from a quick induction sweep to a direct connection.

01

Induction

Stand the Genny4 over the ground to radiate the signal onto nearby buried lines — the fastest way to start a sweep with no connection needed.

02

Direct Connection

Clip the signal directly onto an accessible conductor or valve for a strong, targeted trace on one specific line.

03

Signal Clamp

Apply the signal safely around a live cable or pipe with an accessory clamp — no need to interrupt the supply.

Field Workflow

Apply, Detect, Boost And Locate.

A simple workflow that pairs the Genny4 with a C.A.T4 to find and follow buried utilities with confidence.

Induce · Connect · Clamp

Apply The Signal

Energise the buried utility with the Genny4 using induction, direct connection or a signal clamp.

Two signals at once

Dual-Frequency Output

The patented dual-frequency signal helps locate small-diameter cables like telecoms and street lighting, including spurs.

Deeper & further

Boost The Signal

Switch on Signal Boost so the locate signal travels further, reaches deeper and couples onto utilities more easily.

One gCAT4 system

Locate With C.A.T4

C.A.T4 detects both Genny signals simultaneously for confident tracing and avoidance before you dig.

Genny4 Feature Set

Dual-Frequency Power For Real Site Work.

Dual-Frequency Signal

Find The Small, Difficult Cables.

The Genny4’s patented simultaneous dual-frequency output makes it far easier to pick up small-diameter services — telecoms, street lighting and their spurs — that a single frequency can miss. Every C.A.T4 model detects both signals at the same time.

  • Patented simultaneous dual-frequency output
  • Locates small-diameter cables and spurs
  • Detected on both signals by all C.A.T4 models
  • Better coupling onto congested services
Signal Boost

More Power When The Job Needs It.

A dedicated power boost increases the output signal so operators can locate utilities deeper and over greater distances. When a line runs long or deep, Boost keeps the trace strong from end to end.

  • Increases output signal on demand
  • Locate deeper and over greater distances
  • Signal couples onto utilities more easily
  • Stronger trace on long or buried runs
Built For The Field

Simple, Rugged And Ready To Sweep.

The Genny4 is designed to pair straight out of the case with a C.A.T4 as a complete gCAT4 locating system — light to carry, quick to deploy and dependable across everyday utility avoidance and survey work.

  • Pairs directly with C.A.T4 and SuperC.A.T4
  • Fast induction start with no connections
  • Accessory clamps, leads and connectors
  • Consistent output for repeatable locates
Recommended Kit

Build A Complete Genny Signal Kit.

Pair the Genny4 with the clamps, leads and connectors that make applying a signal faster and more reliable.

Specifications

Technical Details

The Genny4 is supplied to pair with your C.A.T4 locator — ask us to configure the right gCAT4 kit and accessories.

BrandRadiodetection
CategoryPipe & Cable Locator
Product typeSignal generator (transmitter) for C.A.T4
Signal outputPatented simultaneous dual-frequency
Signal BoostOn-demand power boost for depth and distance
Signal applicationInduction, direct connection, signal clamp
Designed to pair withC.A.T4, SuperC.A.T4 cable avoidance tools
Typical targetsSmall-diameter telecoms, street lighting, spurs
PowerAlkaline or rechargeable battery options
SupportLocal training, calibration & repair in Malaysia
Resources

Genny4 & gCAT4 Documents

Works With The C.A.T4 Range

Configure Your gCAT4

Match The Genny4 To Your C.A.T4 Locator.

RD-Palmer can supply the Genny4 with a C.A.T4 or SuperC.A.T4 as a complete gCAT4 system, plus connection accessories, operator training and local calibration support across Malaysia.

See Locator Range